Instrument
Flowmeter > CFW1200 CFW1400 CFW2200

CFW1000/2000 Series flowmeter

General

· Double-tubed pitot tube and light-weight float assure measuring stability at low flow rate and wide rangeability.
· The detachable type allows the measuring of 4 different flow lines by just fitting one indicator unit.
· Easy installation
· Low cost measurement for large pipe sizes
· Two calibration scales for cold and hot water services
· High pressure type up to 2.2 MPa available
· Minimum pressure loss saves running cost
· For both horizontal and vertical piping
· Wide range of pipe sizes from 20mm to 450mm
· Vertical installation type CFW1200 and CFW2400 come into market

Short Specifications

Basic Model CFW1200
Horizontal installation
(fixed)
CFW1400
Vertical installation
(fixed)
CFW2200
(detachable)
Usage Weld a nozzle to side of horizontal pipe and insert flowmeter into the nozzle. You can get flow indication. Weld a nozzle to upper side of horizontal pipe when no space available at the sides of pipe. Insert indicator when needed. One flowmeter can have any 4 different flow ranges for each pipe size. Vertical installation type CFW2400 is also available.
Appearance CDT1000 CDT2000 HDT1000
Fluids Water, hot or cold
Main pipe
size
20mm to 450mm
Flow range Max. 4500 to 35000L/min
Min.10 to 60L/min
Fluid
pressure
Max. 1.0MPa as standard, Max. 2.2MPa as an option
Fluid
temperature
0 to 80°C
Process
connection
R3/4Male
Matrials
Pitot tube: SUS316
Fittings: BC6
Valve: SCS14/SUS316
O-ring: NBR
Body: SCS14/C3604B
Tapered tube:  Heat-resistant glass
Float: Titanium
Pitot tube: SUS316
Fittings: BC6
Hexagon cap nut:  SCS13
Valve: SCS14/SUS316
O-ring: NBR
Body: SCS14/C3604B
Tapered tube:  Heat-resistant glass
Float: Titanium
Indication
accuracy
±5%F.S.