C.M.P. Group > 

Content on this page requires a newer version of Adobe Flash Player.

Get Adobe Flash player

Instrument
Flowmeter > AM-2000 Series

Products | Flow | Metal Tube Variable Area Flowmeters (General purpose) | AM-2000

AM-2000

Outline

AM-2000is the new series of metal tube variable area flowmeters all composwd of metal.
Integrating existing separate functions, AM-2000 has the compact body to mount vertically in the narrow spaces.
Suitable for liquid, gas and steam measurement, it has the easy-to-read indicator with more additional functions for your various applications.

Features

· Standardized installation dimension of 250mm for 15mm to 100mm meter sizes
· Anti-corrosive materials standard!
· Easy maintenance by Modular system
· CE marking
· HART communication option
· Intrinsically safe version (TIIS and ATEX)
  Ex-proof(TIIS) Max. 252°C

Short Specifications

Measuring object Liquids, Gases and Steam
Functions Local indication by pointer and a scale plate
Additional modules
Analog output, HART communication, alarm output,
Totalization
(Refer to Technical Guidance for combination of Mudules.)
Flow range Water(at 20°C)
Max. 10000 to 100000L/h
Min. 5 to 25L/h

Air(at 0MPa, 0°C)
Max. 40 to 400m3/h(nor)
Min. 0.07 to 0.7m3/h(nor)
Available Size 15A to 100A
Fluid pressure 150lbs(10K)class, 300lbs(20K)class
For flange connection, the fluid temperature must be within the pressure-temperature rating of the relevant flange
Fluid temperature -80 to 300°C (In case of local indidcation)
Material SUS 316L (Equ.)
Process connection Flange connection: JIS10KRF,JIS20KRF,ANSI#150/300
Indication accuracy ± 1.6% F.S.
Rangeability 10 : 1
Output DC4 to 20mA
Power supply DC12 to 30V (In case of HART selection DC18 to 30V)
Indicator construction Water proof (IP65)
Intrinsically safe (TIIS Ex ia IIC T4,T2)
(ATEX II 2 G EEx ia IIC T6...T1)

Copyright © 2004 - 2010 C.M.P. Products Co.,Ltd. All rights reserved.