Pump
Metering Pump > Pzi

BPL - Direct driven type - TACMINA Corporation
PZi Series

Popular PZ Series with
Intelligent Brain Now Mounted!!

When the next input signal is entered to a PZi pump during the operation in the multiplication mode, the number of pumping action after operation will be added (max. 9999 times).

<Applications>
  • Chlorine sterilization for small-scale water-supply system,food plants, buildings and swiming pools
  • Injection of chemicals to boilers
  • Chemical injection in the fleld of physics and chemistry plus medical cure
  • Very low flow rate at a high pressure injection of various other liquids

Ο PZi Variation

Series
Function
PZi4 PZi8
Signal
(No of ports)
Analog Input 1
Digital Input 2 4
Output - 2
Power supply to Flow Checker - Ο
Control Manual Digital setting
Auto Analog-Input proportional control O
Pulse-Input proportional control O
Count operation
(batch control)
- O
Interval operation
(timer control)
- O
External stop-signal control O
2-point Level Swich control *1 - Ο
Error/
Alarm
Memory-read error (LCD display only) O
Tank-level alarm w/ 1-point Level Switch
(Pump stop only)
O
W/ 2-point Level Switch
(LCD display/Alarm output/Pump stop)
- Ο
Pulse-Input error O
(display only)
O
Analog-Input error
(LCD display/Alarm output/Pump stop)
O
(display only)
Ο
Lower discharge-volume alarm *2
(LCD display/Alarem output/Pump stop)
O
(display only)
Ο
Easy calibration function -
Momentary discharge-volume display function *2 - O
LCD display 1-row 1-row
(w/ backlight)
*1 When 2-point Level Switch is used
*2 When Flow Checker is used

Ο Secifications: PZi4/PZi/ (S-size w/Relief Valve)

Model
Specification
30R 60R 100R

VT

CE

VT

CF

FT

CE

FT

CF

FT

CT

VTCET
for injection of
boiler chemicals

VT

CE

VT

CF

FT

CE

FT

CF

FT

CT

VT

CE

VT

CF

FT

CE

FT

CF

FT

CT

Max. discharge volume *1 mL/min 30 28 60 100
L/h 1.8 1.68 3.6 6.0
Max. discharge pressure *1 MPa 0.7 *2 1.5 0.7 *2 0.4
Stroke speed 1 to 300 strokes/min (digital setting)
Stroke length 0.5 to 1.0 mm (adjustable by manual dial)
Connection
(hose/tube: I.D × O.D)
Discharge side 4 × 9
(PVC braided hose)
6 × 8
(PE)
1/4 × 3/8
(PE)
6 × 8
(PE)
1/4 × 3/8
(PE)
6 × 8
(FEP)
1/4 × 3/8
(FEP)
4 × 6
(nylon tube)
6 × 11
(PVC braided hose)
6 × 8
(PE)
1/4 × 3/8
(PE)
6 × 8
(PE)
1/4 × 3/8
(PE)
6 × 8
(FEP)
1/4 × 3/8
(FEP)
6 × 11
(PVC braided hose)
6 × 8
(PE)
1/4 × 3/8
(PE)
6 × 8
(PE)
1/4 × 3/8
(PE)
6 × 8
(FEP)
1/4 × 3/8
(FEP)
Suction side 4 ×9
(PVC braided hose)
Relief Valve/Air Release 4 × 6 (soft PVC hose)
Max. allowable viscosity 50 mPa•s
Allowable temperature Ambient temperature: 0 to 40 ºC / Transferring liquid: 0 to 40 ºC (no freezing allowed)
Environmental protection IEC standard: IP65 or equivalent (water- and dust-proof)
Signal Analog-Input
PZi4 : 1 port : Analog signal (4 to 20 mA DC, input resistance : approx. 110Ω) *4
PZi8 : 1 port : Analog signal (4 to 20 mA DC, 0 to 20 mA, input resistance approx. 110Ω) *4
Digital *3 Input
PZi4 : 1 port :

1 port :
High-speed pulse signal (no-voltage contact or open collector, input resistance: approx. 2kΩ, max. number of pulses: 7500 pulse/min, min, pulse width: 4 msec
(ON time) *4
Pump stop signal (no-voltage contact or open collector, input resistance: approx. 2kΩ, min. pulse width: 50 msec (ON time))
PZi8 : 2 ports :

2 ports :
High-speed pulse signal (no-voltage contact or open collector, input resistance: approx. 2kΩ, max. number of pulses: 7500 pulse/min, min, pulse width: 4 msec
(ON time))) *4
Low-speed pulse signal (no-voltage contact or open collector, input resistance: approx. 2kΩ, min. pulse width: 50 msec (ON time))
    Signal assignments :
(4 selectable)
Unassigned, Pulse signal, Stop signal, Reset/Restart signal, Alarm rest signal, Flow Checker signal (only when Flow Checker is used), Level Switch signal (only when Level Switch is used)
Output
PZi8 : only : 2 port : pulse signal (3 mA DC, 25 V or less)
    Signal assignments :
(2 selectable)
Unassigned, Solenoid-operation sync pulse signal, In-opetation signal, Operation and signal, Lamp alarm signal, Low tank-level alarm signal (only when 2-point Level Switch is used), Pulse-Input error signal, Analog-Input error signal, Lower discharge-volume alarm signal (only when Flow Cheker is used)
Power supply to Flow Checker *4 PZi8 only
Operation mode Manual Digital settings: 3 patterns [stroke speed (1 to 300 strokes/min, in 1 stroke/min increments), discharge volume (in 0.1 mL/min increments), percentage (1 to 100%, in 1% increments)]
Auto Analog-Input proportional control *5 Control possible by Proportional Band (PB/variable range: ±1 to ±999%) setting / Shift (S/variable range: 0 to ±100%) setting
Pulse-Input proportional control *5 Control possible by Frequency-division (1/1 to 1/9999) setting / Multiplication (1 to 9999) setting
Count operation
(batch control)
PZi8 only : 1 to 9999 strokes (×1, ×10, ×100, ×1000)
Interval operation
(timer contror)
PZi8 only : ON time : 1 to 9999 min/OFF time : 1 to 9999 min
External stop input control "STP" flashing display, pump stopped
2-point Level Switch Control *6 PZi8 only : [Low tank-level alarm] "E-02" displayed and alarm output / [Lower tank-level alarm] "STP" flashing display and pump stopped
Power supply Rated voltage AC100 to 240V (±10%)
No.of phases/Frequency 1-phase / 50 or 60 Hz
Maximum current 2.2A
Power consumption Max.:220VA/Ave.:16W
Weight 1.9kg 2.0kg 1.9kg 1.9kg
Note:
  1. Conditions: Clean water, room temperature
  2. Though the max. discharge pressure of the 30R models is 1.0 MPa, the Relief Valve operates when 0.7 MPa is exceeded. In applications requiring a discharge pressure of 0.7 MPa or more, ask for a model w/out the Relief Valve, and install a separate relief valve for extra safety.
  3. Though the max. discharte pressure of the 60R models is 0.8 MPa, the Relief Valve operates when 0.7 MPa is exceeded. In applications requiring a discharge pressure of 0.7 MPa or more, ask for a model w/out the Relief Valve, and install a separate relief valve for extra safety.
  4. Combined use of Analog-Input signal and high-speed pulse signal not possible.
  5. For a detailed explanation on signals, see "digital Signal" on Page 26.
  6. For details on the Flow Checker, see "Option" on the back cover.
  7. For details, see "Analog-Input Proportional Control" and "Pulse-Input Proportional Control" on page14.
  8. When 2-point Level Switch is used.

Ο Specifications:PZi4/PZi8 (S-size/L-size)

Model
Specification
30 60 100 300 500

VT

CE

VT

CF

FT

CE

FT

CF

FT

CT

6T

CT

VTCET
for injection
of boiler chemicals

VT

CE

VT

CF

FT

CE

FT

CF

FT

CT

6T

CT

VT

CE

VT

CF

FT

CE

FT

CF

FT

CT

6T

CT

VT

CE

VT

CF

FT

CT

ST

CT

VT

CE

VT

CF

FT

CT

ST

CT

Max. discharge volume *1 mL/min 30 27 28 60 55 100 95 360 330 540 510
L/h 1.8 1.6 1.68 3.6 3.3 6.0 5.7 21.6 19.8 32.4 30.6
Max. discharge pressure *1 MPa 1.0 0.5 1.5 0.8 0.5 0.4 0.3 0.2
Stroke speed 1 to 300 strokes/min (digital setting)
Stroke length Fixed at 1.0 mm 0.2 to 1.5 mm (manual dial)
Connection
(hose/tube: I.D × O.D)
Discharge side 4 × 9
(PVC braided hose)
6 × 8
(PE)
1/4 × 3/8
(PE)
6 × 8
(PE)
1/4 × 3/8
(PE)
6 × 8
(FEP)
1/4 × 3/8
(FEP)
6 × 8
(PTFE)
4 × 6
(nylon tube)
6 × 11
(PVC braided hose)
6 × 8
(PE)
1/4 × 3/8
(PE)
6 × 8
(PE)
1/4 × 3/8
(PE)
6 × 8
(FEP)
1/4 × 3/8
(FEP)
6 × 8
(PTFE)
6 × 11
(PVC braided hose)
6 × 8
(PE)
1/4 × 3/8
(PE)
6 × 8
(PE)
1/4 × 3/8
(PE)
6 × 8
(FEP)
1/4 × 3/8
(FEP)
6 × 8
(PTFE)
12 × 18
(PVC braided hose)
9 × 12
(PE)
3/8 × 1/2
(PE)
12 × 15
(PTFE)
12 × 18
(PVC braided hose)
9 × 12
(PE)
3/8 × 1/2
(PE)
12 × 15
(PTFE)
Suction side 4 × 9
(PVC braided hose)
Air Release 4 × 6 (soft PVC hose) -
Max. allowable viscosity 50 mPa•s
Allowable temperature Ambient temperature: 0 to 40 ºC / Transferring liquid; 0 to 40 ºC (no freezing allowed)
Environmental protection IEC standard; IP65 or equivalent (water- and dust-proof)
Signal Analog-Input
PZi4 : 1 port : Analog signal (4 to 20 mA DC, input resistance : approx. 110Ω) *2
PZi8 : 1 port : Analog signal (4 to 20 mA DC, 0 to 20 mA, input resistance approx. 110Ω) *2
Digital *3 Input
PZi4 : 1 port :

1 port :
High-speed pulse signal (no-voltage contact or open collector, input resistance: approx. 2kΩ, max. number of pulses: 7500 pulse/min, min, pulse width: 4 msec (ON time)) *2
Pump stop signal (no-voltage contact or open collector, input resistance: approx. 2kΩ, min. pulse width: 50 msec (ON time))
PZi8 : 2 ports :

2 ports :
High-speed pulse signal (no-voltage contact or open collector, input resistance: approx. 2kΩ, max. number of pulses: 7500 pulse/min, min, pulse width: 4 msec (ON time)) *2
Low-speed pulse signal (no-voltage contact or open collector, input resistance: approx. 2kΩ, min. pulse width: 50 msec (ON time))
    Signal assignments :
(4 selectable)
Unassigned, Pulse signal, Stop signal, Reset/Restart signal, Alarm rest signal, Flow Checker signal (only when Flow Checker is used), Level Switch signal (only when Level Switch is used)
Output
PZi8 : only : 2 port : Pulse signal (3 mA DC, 25 V or less)
    Signal assignments :
(2 selectable)
Unassigned, Solenoid-operation sync pulse signal, In-opetation signal, Operation and signal, Lamp alarm signal, Low tank-level alarm signal (only when 2-point Level Switch is used), Pulse-Input error signal, Analog-Input error signal, Lower discharge-volume alarm signal (only when Flow Cheker is used)
Power supply to Flow Checker *6 PZi8 only
Operation mode Manual Digital settings: 3 patterns [stroke speed (1 to 300 strokes/min, in 1 stroke/min increments), discharge volume (in 0.1 mL/min increments), percentage (1 to 100%, in 1% increments)]
Auto Analog-Input proportional control *7 Control possible by Proportional Band (PB/variable range: ±1 to ±999%) setting / Shift (S/variable range: 0 to ±100%) setting
Pulse-Input proportional control *7 Control possible by Frequency-division (1/1 to 1/9999) setting / Multiplication (1 to 9999) setting
Count operation
(batch control)
PZi8 only : 1 to 9999 strokes (×1, ×10, ×100, ×1000)
Interval operation
(timer contror)
PZi8 only : ON time : 1 to 9999 min/OFF time : 1 to 9999 min
External stop input control "STP" flashing display, pump stopped
2-point Level Switch Control *8 PZi8 only : [Low tank-level alarm] "E-02" displayed and alarm output / [Lower tank-level alarm] "STP" flashing display and pump stopped
Power supply Rated voltage AC100 to 240V (±10%)
No.of phases/Frequency 1-phase / 50 or 60 Hz
Maximum current 2.2A
Power consumption Max.:220VA/Ave.:16W
Weight 1.9kg 2.0kg 1.9kg 1.9kg 2.0kg 1.9kg 2.0kg 4.0kg 4.2kg 6.0kg 4.0kg 4.2kg 6.0kg
Note:
  1. Conditions: Clean water, room temperature
  2. Combined use of analog input signal and high-speed pulse signal not possible.
  3. For a detailed explanation on signals, see "digital Signal" on Page 26.
  4. For details on the Flow Checker, see "Option" on the back cover.
  5. For details, see "Analog-Input Proportional Control" and "Pulse-Input Proportional Control" on page 14.
  6. When 2-point Level Switch is used.

Ο Liquid-end Material

Model
Specification
VTCE VTCF FTCE FTCF FTCT VTCET
(for injection of boiler chemicals)
6TCT
(S-size)
STCT
(L-size)
Pump head PVC PVDF PVC SUS316 SUS304
Diaphragm PTFE
Check ball Ceramic
O-ring EPDM Fluoro-rubber EPDM Fluoro-rubber Special fluoro-rubber Pafulo®* EPDM PTFE PTFE
Valve seat EPDM Special fluoro-rubber EPDM Special fluoro-rubber PTFE PTFE - -
Joint PVC PVDF PVC SUS316 SUS304
Ball stopper PVC PVDF PTFE (valve stopper) PVC PTFE (valve stopper)
* PTFE for L-size(300/500)

Ο Model Code * Not all model combinations are possible. When selecting the pump model, first check "Specification" and "Liquid-end Material".

PZi8 - 30R - VTCE - 4x9PVC - W - S - JPL
[1]   [2]   [3]   [4]   [5]   [6]   [7]
[1] Series name
    PZi4
PZi8

: Analog / Digital-Input
: Analog / Digital-Input & Digital-Output
[2] Model (discharge volume standard)
[for injection of general chemicals]
    30R
60R
100R
30
60
100
300
500
: 30mL/min (w/ Relief Valve)
: 60mL/min (w/ Relief Valve)
:100mL/min (w/ Relief Valve)
: 30mL/min
: 60mL/min
:100mL/min
:300mL/min
:500mL/min
    [for injection of boiler chemicals]
    30R
30
: 30mL/min (w/ Relief Valve)
: 30mL/min
[3] Liquid-end material
[for injection of general chemicals]
  VTCE
VTCF
FTCE
FTCF
FTCT
6TCT
STCT
 
  [for injeciton of boiler chemicals]
    VTCET    
[4] Hose standard (size/material)
[for injection fo general chemicals]
    4 × 9
6 × 11
12 × 18
6 × 8
9 × 12
1/4 × 3/8
3/8 × 1/2
12 × 15
PVC
PVC
PVC
PE/FEP/PTFE
PE
PE/FEP
PE
PTFE
  [for injection of boiler chemicals]
    4 × 6 PA  
[5] Joint specification
  W
BW
: Standard
: Bolier
[6] Applicable standard
  S
CE
: Standard
: CE marking-compatilble
[7] Power plug
  EUP
ULP
AUP
UKP
JPL
NON
: Euro plug
: UL plug
: Australia plug
: UK plug
: Japan lead wire
: No Cable *
* L-size only (300/500)

Ο Analog signal input

    [PZi4][PZi8] DC4 (0) to 20mA input
(1) Proportional band function
  (A) Pump can operate at 100% even if
the input signal is not 100% (20mA).
  (B) Pump does not operate at full capacity
even if the input signal is 100% (20mA).
(2) Shift function
  (A) Pump discharges the minimum amount
even if the input signal is 0 (4mA).
  (B) Pump does not start injection
until the input exceeds a certain value.

Ο Pulse signal input

(1) Frequency-division (1/1 to 1/9999 adjustable) [PZi4][PZi8]
 
(2) Multiplication (1 to 9999 adjustable)
 

Ο Stop-signal input

  [PZi4][PZi8]

ex.Level switch control

When the tank is empty:
  • The pump stops [PZi4]
  • The pump stops [PZi8]
  • The alarm indication works.
  • Alarm Signal is outputted.

Ο Pulse signal input

(1) Counter (Metering batch injection) [PZi8]
  Pump operates up to max.9999 × 1000 times by the start(switch)signal.
Multiplication setting.(Such as × 1, × 10, × 100 and × 1000.)is available.
Type 31 discharges up to max. 0.99 × 1000. L by one signal. (Indication counts down.)
(2) Interval function  
  ON time and OFF interval can be freely set
from 1 to 9999 min. respectively.
(Operation repeats this setting.)