C.M.P. Group > 

Content on this page requires a newer version of Adobe Flash Player.

Get Adobe Flash player

Pump
Metering Pump > PZD

TACMINA::Products/PZD series
PZD series
Solenoid Pumps Evolve into an Almighty Pump Featuring Higher Durability, Reliability and Operability
<Features>

The PZD pump has been made even easier to operate. Superb basic performance is further supported by direct entry of the discharge volume.

  • Injection amounts can be entered directly.
    This eliminates conversions and ensures reliable injection.
    * Calibration function provided as standard
  • Setpoints can be easily viewed on the LCD.
  • Injection amount can be set according to three patterns:
    •By stroke speed: 1 to 300 spm
    •By discharge volume: ϖϖmL/min
    •By percentage: 1 to 100%

<Applications>
  • Injection of chemicals (acid, alkali, etc.) in water treatment
  • Injection of chemicals in the fields of physics, chemistry and medicine
  • Chlorine sterilization in food processing plants, simple water treatment, buildings and swimming pools
  • Injection of boiler chemicals
  • Injection of nutrients and disinfectants in hydroponic cultivation, and chicken, pig and other livestock farms
  • High-pressure injection of small amounts of other fluids

Ο Specifications:PZD (S-size w/Relief Valve)

Model
Specification
30R 60R 100R
VTCE VTCF FTCE FTCF FTCT VTCET
for injection of
boiler chemicals
VTCE VTCF FTCE FTCF FTCT VTCE VTCF FTCE FTCF FTCT
Max. discharge volume *1 mL/min 30 28 60 100
L/h 1.8 1.68 3.6 6.0
Max. discharge pressure *1 MPa 0.7 *2 1.5 0.7 *2 0.7
Stroke speed 1 to 300 strokes/min (digital setting)
Stroke length Fixed at 1.0 mm
Connection
(hose/tube: I.D × O.D)
Discharge side 4 × 9
(PVC braided hose)
6 × 8
(PE)
1/4 × 3/8
(PE)
6 × 8
(PE)
1/4 × 3/8
(PE)
6 × 8
(FEP)
1/4 × 3/8
(FEP)
4 × 6
(nylon tube)
6 × 11
(PVC braided hose)
6 × 8
(PE)
1/4 × 3/8
(PE)
6 × 8
(PE)
1/4 × 3/8
(PE)
6 × 8
(FEP)
1/4 × 3/8
(FEP)
6 × 11
(PVC braided hose)
6 × 8
(PE)
1/4 × 3/8
(PE)
6 × 8
(PE)
1/4 × 3/8
(PE)
6 × 8
(FEP)
1/4 × 3/8
(FEP)
Suction side 4 ×9
(PVC braided hose)
Relief Valve/Air Release 4 × 6 (soft PVC hose)
Max. allowable viscosity 50 mPa•s
Allowable temperature Ambient temperature: 0 to 40 ºC / Transferring liquid: 0 to 40 ºC (no freezing allowed)
Environmental protection IEC standard: IP65 or equivalent (water- and dust-proof)
Operation mode Manual Digital settings: 3 patterns [stroke speed (1 to 300 strokes/min, in 1 stroke/min increments), discharge volume (in 0.1 mL/min increments), percentage (1 to 100%, in 1% increments)]
Power supply Rated voltage AC100 to 240V (±10%)
No.of phases/Frequency 1-phase / 50 or 60 Hz
Maximum current 2.0A 2.5A 2.5A
Power consumption Max.:200VA/Ave.:15W Max.:250VA/
Ave.:18W
Max.:250VA/Ave.:18W
Weight 1.7kg 1.8kg 1.8kg
Note:
  1. Conditions: Clean water, room temperature
  2. Though the max. discharge pressure of the 30R/60R models is 1.0 MPa, the Relief Valve operates when 0.7 MPa is exceeded. In applications requiring a discharge pressure of 0.7 MPa or more, ask for a model w/out the Relief Valve, and install a separate relief valve for extra safety.

Ο Specifications:PZD (S-size/L-size)

Model
Specification
30 60 100 300 500

VT

CE

VT

CF

FT

CE

FT

CF

FT

CT

6T

CT

VTCET
for injection
of boiler chemicals

VT

CE

VT

CF

FT

CE

FT

CF

FT

CT

6T

CT

VT

CE

VT

CF

FT

CE

FT

CF

FT

CT

6T

CT

VT

CE

VT

CF

FT

CT

ST

CT

VT

CE

VT

CF

FT

CT

ST

CT

Max. discharge volume mL/min 30 27 28 60 55 100 95 360 330 540 510
L/h 1.8 1.6 1.68 3.6 3.3 6.0 5.7 21.6 19.8 32.4 30.6
Max. discharge pressure MPa 1.0 0.5 1.5 1.0 0.5 0.7 0.5 0.3 0.2
Stroke speed 1 to 300 strokes/min (digital setting)
Stroke length Fixed at 1.0 mm 0.2 to 1.5 mm (manual dial)
Connection
(hose/tube: I.D × O.D)
Discharge side 4 × 9
(PVC braided hose)
6 × 8
(PE)
1/4 × 3/8
(PE)
6 × 8
(PE)
1/4 × 3/8
(PE)
6 × 8
(FEP)
1/4 × 3/8
(FEP)
6 × 8
(PTFE)
4 × 6
(nylon tube)
6 × 11
(PVC braided hose)
6 × 8
(PE)
1/4 × 3/8
(PE)
6 × 8
(PE)
1/4 × 3/8
(PE)
6 × 8
(FEP)
1/4 × 3/8
(FEP)
6 × 8
(PTFE)
6 × 11
(PVC braided hose)
6 × 8
(PE)
1/4 × 3/8
(PE)
6 × 8
(PE)
1/4 × 3/8
(PE)
6 × 8
(FEP)
1/4 × 3/8
(FEP)
6 × 8
(PTFE)
12 × 18
(PVC braided hose)
9 × 12
(PE)
3/8 × 1/2
(PE)
12 × 15
(PTFE)
12 × 18
(PVC braided hose)
9 × 12
(PE)
3/8 × 1/2
(PE)
12 × 15
(PTFE)
Suction side 4 × 9
(PVC braided hose)
Air Release 4 × 6 (soft PVC hose) -
Max. allowable viscosity 50 mPa•s
Allowable temperature Ambient temperature: 0 to 40 ºC / Transferring liquid: 0 to 40 ºC (no freezing allowed)
Environmental protection IEC standard: IP65 or equivalent (water- and dust-proof)
Operation mode Manual Digital settings: 3 patterns [stroke speed (1 to 300 strokes/min, in 1 stroke/min increments), discharge volume (in 0.1 mL/min increments), percentage (1 to 100%, in 1% increments)]
Power supply Rated voltage AC100 to 240V(±10%)
No.of phases/Frequency 1-phase / 50 or 60 Hz
Maximum current 2.0A 2.5A 2.5A 3.0A
Power consumption Max.:200VA/Ave.:15W Max.:250VA/
Ave.:18W
Max.:250VA/Ave.:18W Max.:500VA/Ave.:30W
Weight 1.7kg 1.8kg 1.8kg 1.9kg 1.8kg 1.9kg 4.0kg 4.2kg 6.0kg 4.0kg 4.2kg 6.0kg
* Conditions: Clean water, room temperature

Ο Liquid-end Material

Model
Specification
VTCE VTCF FTCE FTCF FTCT VTCET
(for injection of boiler chemicals)
6TCT
(S-size)
STCT
(L-size)
Pump head PVC PVDF PVC SUS316 SUS304
Diaphragm PTFE
Check ball Ceramic
O-ring EPDM Fluoro-rubber EPDM Fluoro-rubber Special fluoro-rubber Pafulo®* EPDM PTFE PTFE
Valve seat EPDM Special fluoro-rubber EPDM Special fluoro-rubber PTFE PTFE - -
Joint PVC PVDF PVC SUS316 SUS304
Ball stopper PVC PVDF PTFE (valve stopper) PVC PTFE (valve stopper)
* PTFE for L-size(300/500)

Ο Model Code * Not all model combinations. When selecting the pump model, first check "Specification" and "Liquid-end Material".

PZD - 30R - VTCE - 4x9PVC - W - S - JPL
    [1]   [2]   [3]   [4]   [5]   [6]
[2] Model (discharge volume standard)
[for injection of general chemicals]
    30R
60R
100R
30
60
100
300
500
: 30mL/min (w/ Relief Valve)
: 60mL/min (w/ Relief Valve)
:100mL/min (w/ Relief Valve)
: 30mL/min
: 60mL/min
:100mL/min
:300mL/min
:500mL/min
    [for injection of boiler chemicals]
    30R
30
: 30mL/min (w/ Relief Valve)
: 30mL/min
  Liquid-end material
[for injection of general chemicals]
  VTCE
VTCF
FTCE
FTCF
FTCT
6TCT
STCT
 
  [for injection of boiler chemicals]
    VTCET  
[3] Hose standard (size/material)
[for injection of general chemicals]
    4 × 9
6 × 11
12 × 18
6 × 8
9 × 12
1/4 × 3/8
3/8 × 1/2
12 × 15
PVC
PVC
PVC
PE/FEP/PTFE
PE
PE/FEP
PE
PTFE
  [for injection of boiler chemicals]
    4 × 6 PA
[4] Joint specification
  W
BW
: Standard
: Bolier
[5] Applicable standard
  S
CE
: Standard
: CE marking-compatible
[6] Power plug
  EUP
ULP
AUP
UKP
JPL
NON
: Euro plug
: UL plug
: Australia plug
: UK plug
: Japan lead wire
: No Cable