C.M.P. Group > 

Content on this page requires a newer version of Adobe Flash Player.

Get Adobe Flash player

Pump
Metering Pump > SXPA / SYPA

TACMINA::Products/Plunger (PA model)
Plunger (PA model)

SXPA1-020 model

Small-volume, high-pressure injection at high precision not affected by pressure fluctuations is possible. The seal life is further extended.

Water TreatmentChemical ProtectionFood

This highly economical and substantial small-capacity series is ideal for extensive applications requiring high-precision and durability.

This compact metering pump comes with five types of pump heads as a quick response to differing site operating conditions and pump applications. Available are models that reliably answer an extensive range of needs including injection of trace amounts, high-pressure injection, and metered injection of high-viscosity liquids or liquids containing slurry. Moreover, multiple-series pump models and pulseless models further extend the scope of application of this series.

<Features>
  • Rigid oil-bath type drive
  • Available in both vertical and horizontal models for selection according to conditions of use and installation
  • Duplex, triplex, and up to six in-series pumps can be manufactured. (also connectable to R series)
  • Liquid-end materials have been specially selected to meet all kinds of liquid injection needs.

(1) Joint
(2) Two-stage valve seat
(3) Check ball
(4) Pump head
(5) V-packing
(6) Plunger
(7) Packing holder
(8) Flexible joint

Ο Performance Specifications

Model Max. discharge volume
(ml/min)
Max. discharge pressure
(MPa)
Strokes per minute (spm) Motor specifications (standard)
50Hz/60Hz
50Hz 60Hz 50Hz 60Hz
SXPA1 -004 4.5 5.5 3.0 53 63 Totally enclosed fan-cooled
outdoor type
3-phase 200 V
0.2kW4P
-006 10 12
-009 23 28
-014 58 70
-020 120 140
-028 230 280 2.0
SYPA1 -004 4 5 3.0 49 59
-006 9 11
-009 22 27
-014 54 65
-020 110 130
-028 220 260 2.0

Ο Standard Liquid-end Materials

Part name
Liquid-end type
Pump head Plunger V-packing Packing holder Check ball Joint O-ring
SNS SUS304 SUS304 NBR SUS304 SUS304 SUS304 NBR
STS SUS304 SUS304 PTFE SUS304 SUS304 SUS304 PTFE

  • Do not use outside the temperature range below as this may result in failure:
      Ambient temperature: 0 to 40 ºC
      Requirement for liquid being handled:
        Liquid temperature: 0 to 100 ºC (no freezing allowed)
        Viscosity: 50 MPa•s or less
      Max. discharge pressure:
        See Performance Specifications.
  • This pump cannot be used for liquids containing slurry or liquids that produce crystals through contact with air as the plunger will be worn.