C.M.P. Group > 

Content on this page requires a newer version of Adobe Flash Player.

Get Adobe Flash player

Pump
Metering Pump > CSII

TACMINA::Products/CSII
Easy, Tough and Safe

This stylishly designed safe TACMINA metering pump is easy-to-use and user-friendly developed with excellent utility, functionality and durability.



Sturdy Tough Body for Outdoor Use  

ϑ3-directional Pump Head

The pump adopts a swivel head that allows you to change the direction the liquid end section faces to suit the installation site. This is handy when incorporating the pump into other equipment or installing the pump in confined locations.

ϑ Terminal Box for Wiring Protection

A terminal box for connecting wiring ducts to the body is provided as standard on all models. This protects wiring from dirt, rainwater and chemicals, which helps prevent current leaks and fire.

ϑ Extensive Range of Liquid-end Materials

For Injection of General Chemicals For Infection of
Boiler Chemicals
For Injection of
High-viscosity Chemicals
For Injection of Sodium Hypochlorite
VTCE/VTCF
Material: PVC
Application: Transfer/injection of general chemicals
FTCE/FTCF/FTCT
Material: PVDF
Application: Transfer/injection of special chemicals
(e.g. strong and mixed acids)
STCT/6TCT
Material: Stainless steel (SUS304/316)
Application: Transfer/injection of solutions/special chemicals
VTCET
Material: PVC
Application: Transfer/injection of boiler chemicals
VT6E
Material: PVC
Application: Transfer/injection of high-viscosity chemicals
(e.g. polymer coagulants)
ATCF(CLCS II)
Material: PMMA
Application: Transfer/injection of chemicals that easily cause gas lock
(e.g. sodium hypochlorite)

Ο Specifications

Item / Model For Injection of General Chemicals w / Relief Valve
10R 30R 60R 100R 300R
VTCE/
VTCF
FTCE/
FTCF/
FTCT
VTCE/
VTCF
FTCE/
FTCF/
FTCT
VTCE/
VTCF
FTCE/
FTCF/
FTCT
VTCE/
VTCF
FTCE/
FTCF/
FTCT
VTCE/
VTCF
FTCE/
FTCF/
FTCT
Max. discharge volume*1(mL/min) 50Hz 10 30 60 100 300
60Hz 12 36 72 120 360
Max. discharge pressure MPa 0.7 *2
Stroke speed
(strokes/min)
50Hz 56 104 102
60Hz 67 125 122
Stroke length (mm) 0 to 2 0 to 3 0 to 6
Connection
(hose/tube ID x OD)
Discharge side 4 x 9 6 x 8 4 x 9 6 x 8 6 x 11 6 x 8 6 x 11 6 x 8 6 x 11 6 x 8
Suction side
Relief Valve/Air Release 4 x 6
Max. allowable viscosity 100 mPa•s
Allowable temperature Ambient 0 to 40ºC
Liquid VTCE/VTCF: 0 to 40ºC
FTCE/FTCF/FTCT: 0 to 60ºC (no freeaing allowed)
Environmental protection IEC529-IPX3 (water-proof)
Weight (kg) 5.0 5.2 5.0 5.2 5.0 5.2 5.0 5.2 5.0 5.2
*1 Conditions: Clean water, room temperature
*2 Though the max. discharge pressure of the pump is 1.0MPa, the Relief Valve operates when 0.7 MPa is exceeded. In applications requiring a discharge pressure of 0.7MPa or more, ask for a model w/out the relief valve, and install a separate relief valve for extra safty.

 

Item / Model For Injection of General Chemicals w/out Relief Valve
10N 10 30N 30 60N 60 100N 100 300N 300 600 1000
VTCE/
VTCF
FTCE/
FTCF/
FTCT
6TCT VTCE/
VTCF
FTCE/
FTCF/
FTCT
6TCT VTCE/
VTCF
FTCE/
FTCF/
FTCT
6TCT VTCE/
VTCF
FTCE/
FTCF/
FTCT
6TCT VTCE/
VTCF
FTCE/
FTCF/
FTCT
6TCT VTCE/
VTCF
FTCE/
FTCF/
FTCT
6TCT VTCE/
VTCF
FTCE/
FTCF/
FTCT
6TCT

Max. discharge volume*

(mL/min)

50Hz 10 30 60 100 300 600 1000
60Hz 12 36 72 120 360 720 1200
Max. discharge pressure* MPa 1.0 0.5 1.0 0.5 1.0 0.5 1.0 0.5 1.0 0.5 0.5 0.3
Stroke speed
(strokes/min)
50Hz 56 104 102
60Hz 67 125 122
Stroke length (mm) 0 to 2 0 to 3 0 to 6
Connection
(hose/tube ID x OD)
Discharge side 4x9 6 x 8 4x9 6 x 8 6x11 6 x 8 6x11 6 x 8 6x11 6 x 8 12x18 12 x 15 12x18 12 x 15
Suction side
Air Release 4 x 6 - 4 x 6 - 4 x 6 - 4 x 6 - 4 x 6 - -
Flange JIS 10K15A - JIS 10K15A - JIS 10K15A - JIS 10K15A - JIS 10K15A - JIS 10K15A - JIS 10K15A -
Max. allowable viscosity 100 mPa•s 50 mPa•s
Allowable temperature Ambient 0 to 40ºC
Liquid VTCE/VTCF: 0 to 40ºC
FTCE/FTCF/FTCT/6TCT/STCT: 0 to 60ºC (no freeaing allowed)
Environmental protection IEC529-IPX3 (water-proof)
Weight (kg) Hose 5.0 5.2 6.3 5.0 5.2 6.3 5.0 5.2 6.3 5.0 5.2 6.3 5.0 5.2 6.3 5.6 5.7 7.3 6.2 6.3 7.9
FLange 5.1 - 5.1 - 5.1 - 5.1 - 5.1 - 5.7 - 6.3 -
* Conditions: Clean water, room temperature

 

Item / Model For Injection of Boiler Chemicals For Injection of
High-viscosity Chemicals
For Injection of Sodium Hypochlorite
(CLCSII)
w / Relief Valve w/out Relief Valve w/out Relief Valve w/ Relief Valve w/out Relief Valve
10R 30R 60R 100R 10N 30N 60N 100N 30N 60N 100N 300N 600 1000 10R 30R 60R 100R 10N 30N 60N 100N
VTCET VT6E ATCF
Max. discharge volume*1
(mL/min)
50Hz 10 30 60 100 10 30 60 100 30 60 100 300 600 1000 10 30 60 100 10 30 60 100
60Hz 12 36 72 120 12 36 72 120 36 72 120 360 720 1200 12 36 72 120 12 36 72 120
Max. discharge pressure MPa 1.5 1.0 0.5 0.3 0.7 *2 1.0
Stroke speed
(strokes/min)
50Hz 56 104 56 104 56 104 102 56 104 56 104
60Hz 67 125 67 125 67 125 122 67 125 67 125
Stroke length (mm) 0 to 2 0 to 3 0 to 2 0 to 3 0 to 2 0 to 3 0 to 6 0 to 2 0 to 3 0 to 2 0 to 3
Connection
(hose/tube ID x OD)
Discharge side 4 x 6 6 x 8 4 x 6 6 x 8 12 x 18 19 x 26 4 x 9 6 x 11 4 x 9 6 x 11
Suction side 4 x 9 6 x 11 4 x 9 6 x 11
Relief Valve/Air Release 4 x 6 4 x 6 - 4 x 6
Max. allowable viscosity 100 mPa•s 2000 mPa•s*3 1000 mPa•s*3 100 mPa•s
Allowable temperature Ambient 0 to 40ºC
Liquid 0 to 40ºC (no freeaing allowed)
Environmental protection IEC529-IPX3 (water-proof)
Weight (kg) 5.0 5.0 5.7 6.3 5.1
*1 Conditions: Clean water, room temperature
*2 Though the max. discharge pressure of the pump is 1.0MPa, the Relief Valve operates when 0.7MPa is exceeded.
In applications requiring a discharge pressure of 0.7MPa or more, ask for a model w/out the relief valve, and install a separate relief valve for extra safty.
*3 When transfering high-viscosity liquids, discharge volume may be lower than the specified volume depending onthe chalacteristic of the qiquid and operating conditions.
Consult TACMINA separately when tranfering high-viscoty liquids.

Ο Liquid-end Material & Corrosion-resistance Table

Part / Model For Injection of General Chemicals

For Injection of
Boiler Chemicals

For Injection of
High-viscosity Chemicals
For Injection of
Sodium Hypochlorite
(CLCSII)
VTCE VTCF FTCE FTCF FTCT 6TCT STCT VTCET VT6E ATCF
Pump Head PVC PVDF SUS316 SUS304 PVC Acrylic (PMMA)
Diaphragm PTFE
Check ball Ceramic SUS316 Ceramic
O-ring EPDM Fluoro-rubber EPDM Fluoro-rubber Special
fluoro-rubber
Pafulo*1
PTFE EPDM Fluoro-rubber
Valve seat EPDM Special
fluoro-rubber
EPDM Special
fluoro-rubber
- - - PTFE EPDM Special
fluoro-rubber
Joint PVC PVDF PTFE SUS316 SUS304 PVC  
Ball stopper PVC PVDF PTFE PTFE
(valve stopper)
PVC - PVC
Ball guide - - - - - PVC -
Compressed coil spring - - - - - SUS304 PVC
Corrosion-resistance Table (0 to 40ºC)
Hydrochloric acid HC - to 20% - to 20% to 38% - -
Sulfuric acid H2SO4 to 60% to 80% to 60% to 80% to 98% 98% -
Acetic acid CHCOOH - to 20% - to 20% to 80% -
Sodium hydroxide NaOH Ο - Ο   Ο -
Aqueous ammonia NH4OH Ο - Ο - Ο -
Sodium hypochiorite NaCO - to 12% - to 12% - to 12%
Hydrogen peroxide H2O2 - to 30% - to 30% to 90% -
Poly-aluminumchloride (PAC) Ο - Ο -
Aluminum sulfate A2(SO4) Ο -
Polymer coagulants - to 2000 mPa•s*2 -
*1 PTFE for 600/1000
*2 To 1000mPa•s for 1000
When transforming high-viscosity liquids, the maximum discharge volume may be lower than the specified volume depending on the characteristics of the liquid and operating conditions.
Consult TACMINA separately when tranfering high-viscoty liquids.
*2 The contesion resistance of materials is greatly affected by temperature, concentration, UV rays, and other emvironmental conditions.
For this reason, this selection does not completely guarantee safty.
*3 The above figures are the corrosion resistance for pump liquid-end materials. Consult TACMINA separately when tranfering high-viscoty liquids.

Ο Motor Specifications

1-phase
Item \ Type 50Hz 60Hz
100V 120V 200V 220V 230V 240V 100V 110V 115V 120V 200V 220V
Output (W) 10W 10W
Rated motor current 0.62A 0.52A 0.30A 0.35A 0.26A 0.28A 0.62A 0.65A 0.59A 0.61A 0.30A 0.32A
Starting current 1.22A 1.00A 0.59A 0.67A 0.51A 0.54A 1.12A 1.26A 0.92A 0.97A 0.56A 0.64A
Number of poles 4 4
3-phase
Item \ Type 50Hz 60Hz
200V 346V 380V 400V 415V 200V 220V 230V 380V 400V 440V
Output 10W 10W
Rated motor current 0.23A 0.14A 0.15A 0.16A 0.17A 0.19A 0.21A 0.22A 0.13A 0.13A 0.15A
Starting current 0.56A 0.33A 0.36A 0.38A 0.40A 0.53A 0.58A 0.61A 0.34A 0.36A 0.40A
Number of poles 4 4

Ο External Dimensions (mm)

[Example] VTCE/VTCF
  VTCE/VTCF (HW hose/tube connection)
10ϖ 30ϖ 60ϖ 100ϖ 300ϖ 600 1000
(A) 250 250 250 250 250 271 279
B 152 152 152 152 152 176 192
C 76 76 76 76 76 79 87
D 76 76 76 76 76 97 87
E 16.5 16.5 16.5 16.5 16.5 23.6 22.6
F 96.5 98.5 98 98 98.5 107 109
(G) 220.5 222.5 222 222 222.5 238 239

 

  VTCE/VTCF (FW flange connection)
10N 30N 60N 100N 300N 600 1000
(A) 292.5 292.5 292.5 292.5 292.5 315 315
B 7 7 7 7 7 2.5 5.5
C 285.5 285.5 285.5 285.5 285.5 312.5 328.5
D 119.5 119.5 119.5 119.5 119.5 12.4 149
E 118.5 118.5 118.5 118.5 118.5 141 51
F 51 51 51 51 51 51 22.6
G 96.5 98.5 98 98 98.5 107 109
(H) 255 257 256.5 256.5 257 265.5 267.5
* the shape and dimensions differ slightly depending on the liquid-end material and connection type.
For details on the external dimensions of other models, consult TACMINA separately.

Ο Model Code

CSII
-
10
-
VTCE
-
HW
-
100V1
-
Y
 
S
 
S
(1)   (2)   (3)   (4)   (5)   (6)   (7)   (8)
(1)Series name (2)Model
(discharge volume standard)
(3)Liquid-end material (4)Joint specification (5)Motor specification
(voltage + phases)
(6)Paint color (7)Power supply connection

(8) General

specification

For Injection of General Chemicals
[1-phase]
100V1 :
120V1 :
200V1 :
100V/110V
115V/120V
230V/240V
[3-phase]
200V3 ::

400V3 :
200V/220V
/230V
346V/380V
/400V/415V
/440V

Y : Yellow
S : Standard
(w/out cable of terminal block)
C : w/ cable (2m)
T : w/terminal block
S : Standard
CSII
w / Relief Valve
10R ;
30R :
60R :
100R :
300R :
10mL
30mL
60mL
100mL
300mL
w/out Relief Valve
10N :
30N :
60N :
100N :
300N :
600 :
1000 :
10mL
30mL
60mL
100mL
300mL
600mL
1000mL
VTCE
VTCF

HW : PVC brainde base
FW : Flunge
*Relief valve is not provided in

the flange speficication.

w / Relief Valve
10R ;
30R :
60R :
100R :
300R :
10mL
30mL
60mL
100mL
300mL
w/out Relief Valve
10 :
30 :
60 :
100 :
300 :
10mL
30mL
60mL
100mL
300mL
FTCE
FTCF
HW : FEP tube
w / Relief Valve
10R ;
30R :
60R :
100R :
300R :
10mL
30mL
60mL
100mL
300mL
w/out Relief Valve
10 :
30 :
60 :
100 :
300 :
600 :
1000 :
10mL
30mL
60mL
100mL
300mL
600mL
1000mL
FTCT HW : PTFE tube
w / Relief Valve
10 ;
30 :
60 :
100 :
300 :
10mL
30mL
60mL
100mL
300mL
6TCT HW : PTFE tube
w/out Relief Valve
600 :
1000 :
600mL
1000mL
STCT HW : PTFE tube
For Injection of Boiler Chemicals
CSII
w / Relief Valve
10R ;
30R :
60R :
100R :
10mL
30mL
60mL
100mL
w/out Relief Valve
10N :
30N :
60N :
100N :
10mL
30mL
60mL
100mL
VTCET BW : PVC braided hose and Nylon tube
For Injection of High-viscosity Chemicals
CSII
w/out Relief Valve
30N :
60N :
100N :
300N :
600 :
1000 :
30mL
60mL
100mL
300mL
600mL
1000mL
VT6E HV : PVC braided hose
For Injection of Sodium Hypochlorite
CLCSII
w / Relief Valve
10R ;
30R :
60R :
100R :
10mL
30mL
60mL
100mL
w/out Relief Valve
10N :
30N :
60N :
100N :
10mL
30mL
60mL
100mL
ATCF HW : PVC braided hose